ISO 9001:2026 is out and IA9100 is next: what it means for measurement

ISO 9001:2026 was published in September 2026, and the aerospace successor to AS9100 is expected to follow it. What is confirmed, what is not, and why the transition is a good moment to tidy up measurement evidence.

Two changes to quality standards are now on every aerospace quality manager's radar. ISO 9001:2026 was published on 16 September 2026 [1]. The aerospace standard built on it, AS9100, is being revised and renumbered as IA9100 by the International Aerospace Quality Group (IAQG) [2].

A lot of commentary about both is speculation. This article sticks to what is confirmed and to the part that matters most for anyone who measures parts for a living.

What is confirmed

  • ISO 9001:2026 is published. ISO's catalogue lists the sixth edition as published in September 2026 [1]. Certification bodies are describing a transition period of about three years, but check the dates your own certification body gives you.
  • IA9100 is not published yet. The IAQG released a first coordination draft for comment in November 2023 and has said it intends to align publication with ISO 9001 [2]. As of late November 2026 no IA9100 publication date or transition deadline has been announced, and estimates in industry press range from late 2026 to mid-2027 [3].
  • AS9100D stays in force until IA9100 is published and its transition period begins.
What this means todayThere is nothing to transition to yet for AS9100 holders. There is time to prepare, and the parts of the quality system that are least likely to change are a sensible place to start.

The measurement requirements will not go away

Whatever the final wording, a quality standard has to deal with whether measurements can be trusted. In ISO 9001:2015 this sits in the clause on monitoring and measuring resources (7.1.5), which covers fitness for purpose, calibration or verification against traceable standards, and what to do when equipment is found out of tolerance. AS9100D adds aerospace-specific expectations on top, and AS9102 governs first article inspection. Check the clause numbering in the 2026 edition and in IA9100 when they reach you, but expect the substance to remain.

That is also where audit findings tend to cluster. In my experience the common gaps are practical ones:

  • calibration certificates that are filed but never compared with the tolerance the instrument is used for;
  • no record of what was done about parts measured with a gauge later found out of tolerance;
  • measurement uncertainty that nobody has estimated for the tightest characteristics;
  • no written decision rule for results close to a limit;
  • software, scripts and inspection programs changed without any check that results are still the same.

Using the transition well

A standards transition makes everyone reread their procedures. It is a good moment to put the measurement part of the quality system on firmer ground, because the work is the same whatever the final IA9100 text says.

  1. Link each critical instrument to the tolerances it checks. A simple table of instrument, calibration uncertainty and tightest tolerance shows at a glance where the measurement is marginal.
  2. Estimate uncertainty where it matters. Follow the GUM approach for the handful of measurements where the ratio of uncertainty to tolerance is worst. A Monte Carlo simulation is useful where the geometry is complex, such as laser tracker networks.
  3. Write down your decision rule. State how results near a limit are treated, for example with guard bands as described in ISO 14253-1, and agree it with your customers.
  4. Validate inspection software and scripts. Keep a reference part or data set and rerun it after any change to an inspection program.
  5. Bring FAI records into the same structure. FAI reports are often the first measurement records a customer or auditor looks at.

Where to start

Start with the instrument-to-tolerance table. It takes a day or two for a typical machine shop, it shows where the real risks are, and it will be useful whatever IA9100 finally says. If you want an independent view of the results, or help estimating uncertainty on the difficult cases, get in touch.

References

  1. ISO. ISO 9001:2026 Quality management systems: Requirements.
  2. NASA Safety and Mission Assurance (April 2024). Status of the development of IA9100.
  3. Glocal Insight (November 2026). IA9100 release date and revision status. A secondary source; check the IAQG and SAE websites for official announcements.
  4. JCGM 100:2008. Evaluation of measurement data: Guide to the expression of uncertainty in measurement (GUM).
  5. ISO 14253-1:2017. Decision rules for verifying conformity or nonconformity with specifications.
About the author

Hammad Kamran, PhD, is the founder of HK Robotics and Metrology. He was metrology lead on Airbus UK’s AutoRAMP programme, metrology systems lead on Wing of Tomorrow, and an automation and metrology engineer at SAFRAN Nacelles.

More about Hammad

← All insights

Have a measurement problem on your line?

Tell me about the part, the process and where it’s going wrong. The first call is free and without obligation.